Difference between revisions of "Guinier plot"
KevinYager (talk | contribs) (→See Also) |
KevinYager (talk | contribs) |
||
Line 1: | Line 1: | ||
A Guinier analysis attempts to extract the size-scale for a structure by fitting the [[scattering]] to an equation of the form: | A Guinier analysis attempts to extract the size-scale for a structure by fitting the [[scattering]] to an equation of the form: | ||
− | :<math>\ln(I) \ | + | :<math>I(q) = I_0 \exp \left( - \frac{R_g^2}{3} q^{2} \right) </math> |
+ | :<math>\ln(I(q)) = \ln(I_0) - (R_g^2/3)q^{2} </math> | ||
==See Also== | ==See Also== | ||
* P. Thiyagarajan, T. S. Burkoth, V. Urban, S. Seifert, T. L. S. Benzinger, D. M. Morgan, D. Gordon, S. C. Meredith and D. G. Lynn [http://journals.iucr.org/j/issues/2000/03/01/issconts.html pH dependent self assembly of beta-amyloid(10-35) and beta-amyloid(10-35)-PEG3000] ''J. Appl. Cryst.'' '''2000''', 33, 535-539. [http://dx.doi.org/10.1107/S0021889899014387 doi: 10.1107/S0021889899014387] | * P. Thiyagarajan, T. S. Burkoth, V. Urban, S. Seifert, T. L. S. Benzinger, D. M. Morgan, D. Gordon, S. C. Meredith and D. G. Lynn [http://journals.iucr.org/j/issues/2000/03/01/issconts.html pH dependent self assembly of beta-amyloid(10-35) and beta-amyloid(10-35)-PEG3000] ''J. Appl. Cryst.'' '''2000''', 33, 535-539. [http://dx.doi.org/10.1107/S0021889899014387 doi: 10.1107/S0021889899014387] | ||
* A. V. Smirnov, I. N. Deryabin and B. A. Fedorov [http://scripts.iucr.org/cgi-bin/paper?aj5257 Small-angle scattering: the Guinier technique underestimates the size of hard globular particles due to the structure-factor effect] ''J. Appl. Cryst.'' '''2015''', 48. [http://dx.doi.org/10.1107/S160057671501078X doi: 10.1107/S160057671501078X] | * A. V. Smirnov, I. N. Deryabin and B. A. Fedorov [http://scripts.iucr.org/cgi-bin/paper?aj5257 Small-angle scattering: the Guinier technique underestimates the size of hard globular particles due to the structure-factor effect] ''J. Appl. Cryst.'' '''2015''', 48. [http://dx.doi.org/10.1107/S160057671501078X doi: 10.1107/S160057671501078X] |
Revision as of 08:17, 25 July 2015
A Guinier analysis attempts to extract the size-scale for a structure by fitting the scattering to an equation of the form:
See Also
- P. Thiyagarajan, T. S. Burkoth, V. Urban, S. Seifert, T. L. S. Benzinger, D. M. Morgan, D. Gordon, S. C. Meredith and D. G. Lynn pH dependent self assembly of beta-amyloid(10-35) and beta-amyloid(10-35)-PEG3000 J. Appl. Cryst. 2000, 33, 535-539. doi: 10.1107/S0021889899014387
- A. V. Smirnov, I. N. Deryabin and B. A. Fedorov Small-angle scattering: the Guinier technique underestimates the size of hard globular particles due to the structure-factor effect J. Appl. Cryst. 2015, 48. doi: 10.1107/S160057671501078X