This page provides brief notes/hints for using the CHX beamline at NSLS-II.
Contents
General
Status
Contact
- Beamline: x1411
- Floor coordinator: x5046
- Control room: x2555
Controls
ophyd
- Start:
- cd ~
- ./ophyd
- Examples:
- wh_pos() : motor positions
- mov(diff_xh, 1.0) : move motor
- movr(diff_xh, -1.0) : relative motion
- movr([diff_xh, diff_yh], [-1.0,-1.0]) : multiple motions
Control System Studio (CSS)
- Start:
- run-css &
- Use:
- Ctrl+mousewheel : zoom
Replay
- ./replay
- Allows access to log entries and graphs.
Instrument
Sample Motion
- Sample motion uses diffractometer. Sample stage is on "horizontal controls" (diff_xh, diff_yh).
- diff_xh : moves sample inboard/outboard.
- Positive motion moves sample outboard (left, beam POV); i.e. beam moves right along sample.
- Negative motion moves sample inboard (right, beam POV); i.e. beam moves left along sample.
- diff_yh : moves sample up/down.
- Positive motion moves sample up; i.e. beam moves down along sample.
- Negative motion moves sample down; i.e. beam moves up along sample.
- diff_zh : moves sample along beam.
- diff_xh : moves sample inboard/outboard.
- Diffractometer also has stages on a "vertical" tower. Because these stages are sitting on a rotation axis (delta-like rotation), their translations (relative to sample) depend on delta.
- diff_xv : moves sample inboard/outboard.
- Positive motion moves stage outboard (left, beam POV); i.e. beam moves right along object.
- Negative motion moves sample inboard (right, beam POV); i.e. beam moves left along object.
- diff_yv : moves sample up/down. Assuming rotation stage is 180°:
- Positive motion moves sample down; i.e. beam moves up along sample.
- Negative motion moves sample up; i.e. beam moves down along sample.
- diff_zv : moves sample along beam.
- diff_xv : moves sample inboard/outboard.
WAXS Detector Motion
- delta : goniometer arm arcing up
- Positive motion rotates RH (axis +vertical), a.k.a CCW (top POV); moves a downstream object left (beam POV); i.e. beam moves right along object.
- Negative motion rotates LH (axis +vertical), a.k.a CW (top POV); moves a downstream object right (beam POV); i.e. beam moves left along object.
- gamma : goniometer in-plane rotation
- Positive motion rotates arm RH (axis +outboard), a.k.a CCW (sample POV); moves a downstream object down (beam POV); i.e. beam moves up along object.
- Negative motion rotates arm LH (axis +outboard), a.k.a CW (sample POV); moves a downstream object up (beam POV); i.e. beam moves down along object.
Detectors
X-ray Eye
- Visualization of direct x-ray beam.
- Fluorescent crystal being imaged by conventional CCD camera.
WAXS Detector
- Eiger1M
- To start:
- Array callbacks: Enable
- To debug:
- http_proxy= google-chrome
- http://10.11.1.3/data/
- Saves data as HDF5
Other
Cameras
- camonitor
- XF:11IDB-BI{Cam:08}Stats1:Total:RBV
- http://xf11idb-cam1.cs.nsls2.local/view/index.shtml