− | Thus a straight line in a plot of ln(''I'') vs. ''[[q]]''<sup>2</sup> is indicative of Guinier scaling and suggests that a system is essentially monodisperse, and can therefore be used as a means of quality control before further data analysis (e.g. [[Form factor]]). Such an analysis is typically only done with the low-''q'' portion of the data. | + | Thus a straight line in a plot of ln(''I'') vs. ''[[q]]''<sup>2</sup> is indicative of Guinier scaling and suggests that a system is essentially monodisperse, and can therefore be used as a means of quality control before further data analysis (e.g. [[Form factor]]). Such an analysis is typically only done with the low-''q'' portion of the data. |
Smaller particles require measurement of lower ''[[q]]'' for Guinier analysis, as Guinier scaling is only maintained up to a certain maximum ''q'': | Smaller particles require measurement of lower ''[[q]]'' for Guinier analysis, as Guinier scaling is only maintained up to a certain maximum ''q'': |
Revision as of 16:17, 11 August 2020
Guinier analysis attempts to extract the size-scale for a structure by fitting the scattering to an equation of the form
or equivalently,
Thus a straight line in a plot of ln(I) vs. q2 is indicative of Guinier scaling and suggests that a system is essentially monodisperse, and can therefore be used as a means of quality control before further data analysis (e.g. Form factor). Such an analysis is typically only done with the low-q portion of the data.
Smaller particles require measurement of lower q for Guinier analysis, as Guinier scaling is only maintained up to a certain maximum q:
- For spherical particles,
- For elongated particles,
See Also
- P. Thiyagarajan, T. S. Burkoth, V. Urban, S. Seifert, T. L. S. Benzinger, D. M. Morgan, D. Gordon, S. C. Meredith and D. G. Lynn pH dependent self assembly of beta-amyloid(10-35) and beta-amyloid(10-35)-PEG3000 J. Appl. Cryst. 2000, 33, 535-539. doi: 10.1107/S0021889899014387
- A. V. Smirnov, I. N. Deryabin and B. A. Fedorov Small-angle scattering: the Guinier technique underestimates the size of hard globular particles due to the structure-factor effect J. Appl. Cryst. 2015, 48. doi: 10.1107/S160057671501078X
- C. D. Putnam Guinier peak analysis for visual and automated inspection of small-angle X-ray scattering data J. Appl. Cryst. 2016, 49. doi: 10.1107/S1600576716010906