Difference between revisions of "X9"

From GISAXS
Jump to: navigation, search
(Created page with "'''X9''' is an x-ray synchrotron beamline at the National Synchrotron Light Source (NSLS), Brookhaven National Lab (BNL). It is a joint beamline between the NS...")
 
Line 1: Line 1:
 
'''X9''' is an [[x-ray]] [[synchrotron]] [[beamline]] at the National Synchrotron Light Source ([[NSLS]]), Brookhaven National Lab (BNL). It is a joint beamline between the NSLS and the [http://www.bnl.gov/cfn/ Center for Functional Nanomaterials]. The instrument is optimized for doing Small-Angle X-ray Scattering ([[SAXS]]) and Grazing-Incidence Small-Angle X-ray Scattering ([[GISAXS]]), as well as wide-angle Grazing-Incidence X-ray Diffraction (GID/GIXD/[[GIWAXS]]).
 
'''X9''' is an [[x-ray]] [[synchrotron]] [[beamline]] at the National Synchrotron Light Source ([[NSLS]]), Brookhaven National Lab (BNL). It is a joint beamline between the NSLS and the [http://www.bnl.gov/cfn/ Center for Functional Nanomaterials]. The instrument is optimized for doing Small-Angle X-ray Scattering ([[SAXS]]) and Grazing-Incidence Small-Angle X-ray Scattering ([[GISAXS]]), as well as wide-angle Grazing-Incidence X-ray Diffraction (GID/GIXD/[[GIWAXS]]).
 +
 +
[[Image:X9_NSLS_01.jpg|400px]][[Image:X9_NSLS_02.jpg|400px]]
 +
 +
==Capabilities==
 +
 +
===q-range===
 +
The instrument can capture data on both a SAXS and WAXS detector (either simultaneously or sequentially). The '''q'''-range depends on the sample-detector distance:
 +
* '''5.4 m:''' 0.002 Å<sup>−1</sup> to 0.1 Å<sup>−1</sup> (314 nm to 6.3 nm)
 +
* '''4.1 m:''' 0.005 Å<sup>−1</sup> to 0.2 Å<sup>−1</sup> (125 nm to 3.5 nm)
 +
* '''3.0 m:''' 0.004 Å<sup>−1</sup> to 0.2 Å<sup>−1</sup> (157 nm to 3.5 nm)
 +
* '''2.0 m:''' 0.010 Å<sup>−1</sup> to 0.4 Å<sup>−1</sup> (63 nm to 1.6 nm)
 +
* '''1.5 m:''' 0.011 Å<sup>−1</sup> to 0.45 Å<sup>−1</sup> (63 nm to 1.4 nm)
 +
 +
* '''[http://beamlines.ps.bnl.gov/forms/BLOSA/X9.pdf BLOSA]''' training

Revision as of 15:46, 3 June 2014

X9 is an x-ray synchrotron beamline at the National Synchrotron Light Source (NSLS), Brookhaven National Lab (BNL). It is a joint beamline between the NSLS and the Center for Functional Nanomaterials. The instrument is optimized for doing Small-Angle X-ray Scattering (SAXS) and Grazing-Incidence Small-Angle X-ray Scattering (GISAXS), as well as wide-angle Grazing-Incidence X-ray Diffraction (GID/GIXD/GIWAXS).

X9 NSLS 01.jpgX9 NSLS 02.jpg

Capabilities

q-range

The instrument can capture data on both a SAXS and WAXS detector (either simultaneously or sequentially). The q-range depends on the sample-detector distance:

  • 5.4 m: 0.002 Å−1 to 0.1 Å−1 (314 nm to 6.3 nm)
  • 4.1 m: 0.005 Å−1 to 0.2 Å−1 (125 nm to 3.5 nm)
  • 3.0 m: 0.004 Å−1 to 0.2 Å−1 (157 nm to 3.5 nm)
  • 2.0 m: 0.010 Å−1 to 0.4 Å−1 (63 nm to 1.6 nm)
  • 1.5 m: 0.011 Å−1 to 0.45 Å−1 (63 nm to 1.4 nm)