==Controls==
 
==Controls==
 
===[[ophyd]]===
 
===[[ophyd]]===
* wh_pos() : motor positions
+
* Start:
* mov(diff_xh, 1.0) : move motor
+
** cd ~
* movr(diff_xh, -1.0) : relative motion
+
** ./ophyd
* movr([diff_xh, diff_yh], [-1.0,-1.0]) : multiple motions
+
* Examples:
 +
** wh_pos() : motor positions
 +
** mov(diff_xh, 1.0) : move motor
 +
** movr(diff_xh, -1.0) : relative motion
 +
** movr([diff_xh, diff_yh], [-1.0,-1.0]) : multiple motions
  
===CSS===
+
===[[Control System Studio]] (CSS)===
* [[Control System Studio]]
+
* Start:
 +
** run-css &
 +
* Use:
 +
** Ctrl+mousewheel : zoom
  
 
===Replay===
 
===Replay===
 
* ./replay
 
* ./replay
 
* Allows access to log entries and graphs.
 
* Allows access to log entries and graphs.
 +
 +
==Instrument==
 +
===Sample Motion===
 +
* Sample motion uses diffractometer. Sample stage is on "horizontal controls" (diff_xh, diff_yh).
 +
** diff_xh : moves sample inboard/outboard.
 +
*** Positive motion moves sample outboard (left, beam POV); i.e. beam moves right along sample.
 +
*** Negative motion moves sample inboard (right, beam POV); i.e. beam moves left along sample.
 +
** diff_yh : moves sample up/down.
 +
*** Positive motion moves sample up; i.e. beam moves down along sample.
 +
*** Negative motion moves sample down; i.e. beam moves up along sample.
 +
* Diffractometer also has
 +
===WAXS Detector Motion==
 +
* delta : goniometer arm arcing up
 +
* gamma : goniometer in-plane rotation

Revision as of 12:31, 31 July 2015

This page provides brief notes/hints for using the CHX beamline at NSLS-II.

General

Status

Contact

  • Beamline: x1411
  • Floor coordinator: x5046
  • Control room: x2555

Controls

ophyd

  • Start:
    • cd ~
    • ./ophyd
  • Examples:
    • wh_pos() : motor positions
    • mov(diff_xh, 1.0) : move motor
    • movr(diff_xh, -1.0) : relative motion
    • movr([diff_xh, diff_yh], [-1.0,-1.0]) : multiple motions

Control System Studio (CSS)

  • Start:
    • run-css &
  • Use:
    • Ctrl+mousewheel : zoom

Replay

  • ./replay
  • Allows access to log entries and graphs.

Instrument

Sample Motion

  • Sample motion uses diffractometer. Sample stage is on "horizontal controls" (diff_xh, diff_yh).
    • diff_xh : moves sample inboard/outboard.
      • Positive motion moves sample outboard (left, beam POV); i.e. beam moves right along sample.
      • Negative motion moves sample inboard (right, beam POV); i.e. beam moves left along sample.
    • diff_yh : moves sample up/down.
      • Positive motion moves sample up; i.e. beam moves down along sample.
      • Negative motion moves sample down; i.e. beam moves up along sample.
  • Diffractometer also has

=WAXS Detector Motion

  • delta : goniometer arm arcing up
  • gamma : goniometer in-plane rotation