Difference between revisions of "CHX:Hints"

From GISAXS
Jump to: navigation, search
(Created page with "This page provides brief notes/hints for using the CHX beamline at NSLS-II. ==Status== * [http://status.nsls2.bnl.gov/ NSLS-II machine status] ([https://twitter.com/n...")
 
(Controls)
 
(12 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
This page provides brief notes/hints for using the [[CHX]] beamline at [[NSLS-II]].
 
This page provides brief notes/hints for using the [[CHX]] beamline at [[NSLS-II]].
  
==Status==
+
==General==
 +
===Status===
 
* [http://status.nsls2.bnl.gov/ NSLS-II machine status] ([https://twitter.com/nsls2ops twitter])
 
* [http://status.nsls2.bnl.gov/ NSLS-II machine status] ([https://twitter.com/nsls2ops twitter])
 
* [https://controlsweb01.nsls2.bnl.gov/logbook-chx/index.html#2018_1 CHX olog]
 
* [https://controlsweb01.nsls2.bnl.gov/logbook-chx/index.html#2018_1 CHX olog]
 +
 +
===Contact===
 +
* Beamline: x1411
 +
* Floor coordinator: x5046
 +
* Control room: x2555
 +
 +
==[[NSLS-II Control Software|Controls]]==
 +
[[NSLS-II Control Software]]
 +
 +
===[[ophyd]]===
 +
* Start:
 +
** cd ~
 +
** ./ophyd
 +
* Examples:
 +
** wh_pos() : motor positions
 +
** mov(diff_xh, 1.0) : move motor
 +
** movr(diff_xh, -1.0) : relative motion
 +
** movr([diff_xh, diff_yh], [-1.0,-1.0]) : multiple motions
 +
 +
===[[Control System Studio]] (CSS)===
 +
* Start:
 +
** run-css &
 +
* Use:
 +
** Ctrl+mousewheel : zoom
 +
 +
===Replay===
 +
* ./replay
 +
* Allows access to log entries and graphs.
 +
 +
==Instrument==
 +
===Sample Motion===
 +
* Sample motion uses diffractometer. Sample stage is on "horizontal controls" (diff_xh, diff_yh).
 +
** diff_xh : moves sample inboard/outboard.
 +
*** Positive motion moves sample outboard (left, beam POV); i.e. beam moves right along sample.
 +
*** Negative motion moves sample inboard (right, beam POV); i.e. beam moves left along sample.
 +
** diff_yh : moves sample up/down.
 +
*** Positive motion moves sample up; i.e. beam moves down along sample.
 +
*** Negative motion moves sample down; i.e. beam moves up along sample.
 +
** diff_zh : moves sample along beam.
 +
 +
* Diffractometer also has stages on a "vertical" tower. Because these stages are sitting on a rotation axis (delta-like rotation), their translations (relative to sample) depend on delta.
 +
** diff_xv : moves sample inboard/outboard.
 +
*** Positive motion moves stage outboard (left, beam POV); i.e. beam moves right along object.
 +
*** Negative motion moves sample inboard (right, beam POV); i.e. beam moves left along object.
 +
** diff_yv : moves sample up/down. Assuming rotation stage is 180°:
 +
*** Positive motion moves sample down; i.e. beam moves up along sample.
 +
*** Negative motion moves sample up; i.e. beam moves down along sample.
 +
** diff_zv : moves sample along beam.
 +
 +
===WAXS Detector Motion===
 +
* delta : goniometer arm arcing up
 +
** Positive motion rotates RH (axis +vertical), a.k.a CCW (top POV); moves a downstream object left (beam POV); i.e. beam moves right along object.
 +
** Negative motion rotates LH (axis +vertical), a.k.a CW (top POV); moves a downstream object right (beam POV); i.e. beam moves left along object.
 +
* gamma : goniometer in-plane rotation
 +
** Positive motion rotates arm RH (axis +outboard), a.k.a CCW (sample POV); moves a downstream object down (beam POV); i.e. beam moves up along object.
 +
** Negative motion rotates arm LH (axis +outboard), a.k.a CW (sample POV); moves a downstream object up (beam POV); i.e. beam moves down along object.
 +
 +
 +
==Detectors==
 +
===X-ray Eye===
 +
* Visualization of direct x-ray beam.
 +
* Fluorescent crystal being imaged by conventional CCD camera.
 +
 +
===WAXS Detector===
 +
* Eiger1M
 +
* To start:
 +
** Array callbacks: Enable
 +
* To debug:
 +
** http_proxy= google-chrome
 +
** http://10.11.1.3/data/
 +
* Saves data as [[HDF5]]
 +
 +
==Other==
 +
===Logging ([[Olog]])===
 +
* https://controlsweb01.nsls2.bnl.gov/logbook-chx/
 +
===Cameras===
 +
* camonitor
 +
* XF:11IDB-BI{Cam:08}Stats1:Total:RBV
 +
* http://xf11idb-cam1.cs.nsls2.local/view/index.shtml

Latest revision as of 17:01, 29 September 2015

This page provides brief notes/hints for using the CHX beamline at NSLS-II.

General

Status

Contact

  • Beamline: x1411
  • Floor coordinator: x5046
  • Control room: x2555

Controls

NSLS-II Control Software

ophyd

  • Start:
    • cd ~
    • ./ophyd
  • Examples:
    • wh_pos() : motor positions
    • mov(diff_xh, 1.0) : move motor
    • movr(diff_xh, -1.0) : relative motion
    • movr([diff_xh, diff_yh], [-1.0,-1.0]) : multiple motions

Control System Studio (CSS)

  • Start:
    • run-css &
  • Use:
    • Ctrl+mousewheel : zoom

Replay

  • ./replay
  • Allows access to log entries and graphs.

Instrument

Sample Motion

  • Sample motion uses diffractometer. Sample stage is on "horizontal controls" (diff_xh, diff_yh).
    • diff_xh : moves sample inboard/outboard.
      • Positive motion moves sample outboard (left, beam POV); i.e. beam moves right along sample.
      • Negative motion moves sample inboard (right, beam POV); i.e. beam moves left along sample.
    • diff_yh : moves sample up/down.
      • Positive motion moves sample up; i.e. beam moves down along sample.
      • Negative motion moves sample down; i.e. beam moves up along sample.
    • diff_zh : moves sample along beam.
  • Diffractometer also has stages on a "vertical" tower. Because these stages are sitting on a rotation axis (delta-like rotation), their translations (relative to sample) depend on delta.
    • diff_xv : moves sample inboard/outboard.
      • Positive motion moves stage outboard (left, beam POV); i.e. beam moves right along object.
      • Negative motion moves sample inboard (right, beam POV); i.e. beam moves left along object.
    • diff_yv : moves sample up/down. Assuming rotation stage is 180°:
      • Positive motion moves sample down; i.e. beam moves up along sample.
      • Negative motion moves sample up; i.e. beam moves down along sample.
    • diff_zv : moves sample along beam.

WAXS Detector Motion

  • delta : goniometer arm arcing up
    • Positive motion rotates RH (axis +vertical), a.k.a CCW (top POV); moves a downstream object left (beam POV); i.e. beam moves right along object.
    • Negative motion rotates LH (axis +vertical), a.k.a CW (top POV); moves a downstream object right (beam POV); i.e. beam moves left along object.
  • gamma : goniometer in-plane rotation
    • Positive motion rotates arm RH (axis +outboard), a.k.a CCW (sample POV); moves a downstream object down (beam POV); i.e. beam moves up along object.
    • Negative motion rotates arm LH (axis +outboard), a.k.a CW (sample POV); moves a downstream object up (beam POV); i.e. beam moves down along object.


Detectors

X-ray Eye

  • Visualization of direct x-ray beam.
  • Fluorescent crystal being imaged by conventional CCD camera.

WAXS Detector

Other

Logging (Olog)

Cameras