The '''Complex Materials Scattering''' ('''CMS''') [[beamline]] at [[NSLS-II]] is a [[synchrotron]] instrument focused on [[x-ray]] [[scattering]]. It is located at 11-BM ([[bending magnet]] port) on the NSLS-II floor, and features a [[three-pole wiggler]] source. It can perform [[SAXS]] and [[WAXS]] experiments, focusing on high-throughput and 'intelligent' machine-guided exploration of parameter spaces.
+
The '''Complex Materials Scattering''' ('''CMS''') [[beamline]] at [[NSLS-II]] is a [[synchrotron]] instrument focused on [[x-ray]] [[scattering]]. It is located at 11-BM ([[bending magnet]] port) on the NSLS-II floor, and features a [[three-pole wiggler]] source. It can perform [[SAXS]] and [[WAXS]] experiments, focusing on ambitious synchrotron experiments, including [[in-situ]] or [[operando]] studies of materials during synthesis, processing, or operation; and autonomous experiments including high-throughput explorations and 'intelligent' machine-guided exploration of parameter spaces.
  
 
[[Image:CMS_beamline01.jpg|thumb|500px|center]]
 
[[Image:CMS_beamline01.jpg|thumb|500px|center]]
  
 
==Capabilities==
 
==Capabilities==
CHX can perform a variety of experiments:
+
CMS can perform a variety of experiments:
 
* [[SAXS]]
 
* [[SAXS]]
 
* [[GISAXS]]
 
* [[GISAXS]]

Revision as of 08:17, 17 June 2018

Logo CMS 20.png

The Complex Materials Scattering (CMS) beamline at NSLS-II is a synchrotron instrument focused on x-ray scattering. It is located at 11-BM (bending magnet port) on the NSLS-II floor, and features a three-pole wiggler source. It can perform SAXS and WAXS experiments, focusing on ambitious synchrotron experiments, including in-situ or operando studies of materials during synthesis, processing, or operation; and autonomous experiments including high-throughput explorations and 'intelligent' machine-guided exploration of parameter spaces.

CMS beamline01.jpg

Capabilities

CMS can perform a variety of experiments:

Performance

Energy

  • Can perform experiments from 10 keV to 17 keV.
  • Energy resolution (double multilayers): 10−3

q-range

  • 0.003 Å−1 to 4.2 Å−1 (209 nm to 0.15 nm)

Resolution

Ultimate resolution (detector pixel limited) is 0.0002 Å−1.

beam size beam divergence pixel size pixel FW @ 5 m pixel FW @ 5 m, 13.5 keV resolution resolution
(mm) (mrad) (mm) (mrad) −1) FWHM (Å−1) σ (Å−1)
0.200 0.10 0.172 0.03 0.00024 0.0007 0.00030
0.100 0.05 0.172 0.03 0.00024 0.0002 0.00008

Flux

Full Beam

At start of endstation (bim3 ionchamber):

  • 1.6 ×1012 ph/s/0.1%bw (1.5 × 0.1 mrad; diagnostic mesh in-place; 13.5 keV, 250 mA ring current)
  • 1.5 ×1111 ph/s/0.1%bw (0.1 × 0.1 mrad; 13.5 keV, 250 mA ring current)

Near sample position, full beam (no slits):

  • 1.3 ×1012 ph/s (13.5 keV, 250 mA ring current)

Normal Beam

For 13.5 keV, 250 mA ring current:

S4 slits size (mm) beam divergence (mrad) beam size at sample position (μm) beam flux at sample/detector (ph/s) olog
1.000 H × 1.000 V 0.10 H × 0.10 V 2.1×1011 834_2
0.200 H × 0.200 V 0.10 H × 0.10 V 1.2×1011 834_2
0.100 H × 0.100 V 0.10 H × 0.10 V 3.4×1010 834_2
0.050 H × 0.050 V 0.10 H × 0.10 V 8.6×109 834_2
0.020 H × 0.020 V 0.10 H × 0.10 V 1.1×109 834_2
0.100 H × 0.020 V 0.10 H × 0.10 V 5.4×109 834_2
0.100 H × 0.010 V 0.10 H × 0.10 V 1.9×109 834_2

Small Beam

For 13.5 keV, 250 mA ring current:

S4 slits size (mm) beam divergence (mrad) beam V size at sample position (μm) beam flux at sample/detector (ph/s) olog
0.100 H × 0.010 V 0.10 H × 0.10 V 33 2×109 819_1
0.100 H × 0.010 V 0.10 H × 0.05 V 22 1×109 821_1
  • With divergence of 0.1 mrad H x 0.05 mrad V and S4 beam size of 0.1 mm H x 0.01 mm V, "knife-edge" smy scan implies beam FWHM of ~ 22 um V at sample and flux of 1e+9 cts/s as measured at Pilatus (with attenuation factor included).

With divergence of 0.1 mrad H x 0.1 mrad V and S4 beam size of 0.1 mm H x 0.01 mm V, "knife-edge" smy scan implies beam FWHM of ~ 33 um V at sample and flux of 2e+9 cts/s as measured at

Beam Size

  • Typical 50-100 µm
  • Beam can be shaped (using slits) to 10 µm.

Configuration

CMS is a flexible SAXS/WAXS instrument. The instrument has two detectors (SAXS and WAXS) that can be repositioned as needed for experiments. The sample environment is flexible, with the ability to measure samples in vacuum or in air.

CMS can accommodate a wide range of sample holders and customized (in-situ or operando) sample environments.

Access

CMS is available for general user experiments. Proposals can be submitted through the NSLS-II proposal system, and through the CFN proposal system. Interested users should contact beamline staff.

Contact

  • Beamline phone number: 631-344-1911

Beamline Staff

Masa Fukuto (beamline lead)
  • email: fukuto@bnl.gov
  • office phone: 631-344-5256
  • office location: Bldg. 744 (green LOB of NSLS-II), room 4L108
Masa Fukuto01.jpeg
Ruipeng Li (beamline staff)
  • email: rli@bnl.gov
  • office phone: 631-344-5994
  • office location: Bldg. 744 (green LOB of NSLS-II), room 4L140
Ruipeng Li01.jpg
Kevin Yager (partner user beamline staff)
  • email: kyager@bnl.gov
  • office phone: 631-344-7608
  • office location: Bldg. 735 (CFN), room 2018 (2nd floor, east side)
Kevin Yager01.jpg

Training

Software

See Also