Difference between revisions of "Labscale"

From GISAXS
Jump to: navigation, search
(Vendors)
(Vendors)
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
The term '''labscale''' is informally used to refer to small-scale [[x-ray]] instruments used for diffraction or [[scattering]], in comparison to [[synchrotron]] [[beamlines]]. These may also be called '''in-house''' of '''benchtop''' instruments.
 
The term '''labscale''' is informally used to refer to small-scale [[x-ray]] instruments used for diffraction or [[scattering]], in comparison to [[synchrotron]] [[beamlines]]. These may also be called '''in-house''' of '''benchtop''' instruments.
  
Labscale instruments typically use a rotating anode as an x-ray source. Their flux is much lower than a synchrotron (which is 3-6 orders-of-magnitude brighter). Labscale instruments also typically haver larger beam sizes, worse [[instrumental resolution|resolution]], and lower coherence. Nevertheless, useful data can be obtained on many systems, especially [[Tutorial:Qualitative_inspection#Scattering_Intensity|strongly scattering]] samples.
+
Labscale instruments typically use a rotating anode as an x-ray source. Their flux is much lower than a synchrotron (which is 3-6 orders-of-magnitude brighter); e.g, 10<sup>7</sup> to 10<sup>8</sup> photons/s. Labscale instruments also typically haver larger beam sizes, worse [[instrumental resolution|resolution]], and lower coherence. Nevertheless, useful data can be obtained on many systems, especially [[Tutorial:Qualitative_inspection#Scattering_Intensity|strongly scattering]] samples.
  
 
==Vendors==
 
==Vendors==
Line 8: Line 8:
 
* [http://www.rigaku.com/en Rigaku] ([http://www.rigaku.com/en/applications/SAXS_nanotechnology SAXS])
 
* [http://www.rigaku.com/en Rigaku] ([http://www.rigaku.com/en/applications/SAXS_nanotechnology SAXS])
 
* [http://www.xenocs.com/en/ Xenocs] ([http://www.xenocs.com/en/solutions/xeuss-saxs-waxs-laboratory-beamline/ SAXS])
 
* [http://www.xenocs.com/en/ Xenocs] ([http://www.xenocs.com/en/solutions/xeuss-saxs-waxs-laboratory-beamline/ SAXS])
 +
** [http://saxslab.com/ SAXSLAB] ([http://saxslab.com/ganesha/ SAXS])
 +
** [http://www.molmexscientific.com/ Molmex]

Latest revision as of 11:26, 4 January 2017

The term labscale is informally used to refer to small-scale x-ray instruments used for diffraction or scattering, in comparison to synchrotron beamlines. These may also be called in-house of benchtop instruments.

Labscale instruments typically use a rotating anode as an x-ray source. Their flux is much lower than a synchrotron (which is 3-6 orders-of-magnitude brighter); e.g, 107 to 108 photons/s. Labscale instruments also typically haver larger beam sizes, worse resolution, and lower coherence. Nevertheless, useful data can be obtained on many systems, especially strongly scattering samples.

Vendors