Difference between revisions of "CHX"
KevinYager (talk | contribs) (→See Also) |
KevinYager (talk | contribs) (→q-range) |
||
(12 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | [[Image:logo_CHX_20.png|thumb|200px|right]] | ||
+ | |||
The '''Coherent Hard X-ray''' ('''CHX''') [[beamline]] at [[NSLS-II]] is a [[synchrotron]] [[undulator]]-based instrument dedicated to nanometer-scale dynamics. It sits at beamport 11-[[Insertion device|ID]]. The instrument is primarily focused on enabling [[XPCS]] (X-ray Photon Correlation Spectroscopy) measurements of [[coherent speckle|speckle]] fluctuation; measurement of the time correlation function can be used to quantify dynamics. Due to the high coherent brightness of the NSLS-II storage ring, CHX will enable measurements over timescales previously inaccessible. | The '''Coherent Hard X-ray''' ('''CHX''') [[beamline]] at [[NSLS-II]] is a [[synchrotron]] [[undulator]]-based instrument dedicated to nanometer-scale dynamics. It sits at beamport 11-[[Insertion device|ID]]. The instrument is primarily focused on enabling [[XPCS]] (X-ray Photon Correlation Spectroscopy) measurements of [[coherent speckle|speckle]] fluctuation; measurement of the time correlation function can be used to quantify dynamics. Due to the high coherent brightness of the NSLS-II storage ring, CHX will enable measurements over timescales previously inaccessible. | ||
Line 9: | Line 11: | ||
* [[SAXS]] | * [[SAXS]] | ||
* [[WAXS]] | * [[WAXS]] | ||
− | * All of these experiments can also be performed in grazing-incidence mode ( | + | * All of these experiments can also be performed in grazing-incidence mode ([[GISAXS]]/[[GIWAXS]], etc.). |
==Performance== | ==Performance== | ||
Line 17: | Line 19: | ||
===q-range=== | ===q-range=== | ||
− | + | * Maximum SAXS detector distance is 15 m, offering access to very small ''q'' values. | |
+ | ** E.g. at 9 keV, and SAXS detector at 15m, one could reach q = 0.00006 Å<sup>−1</sup> (realspace distance of 9 microns). | ||
+ | * Goniometer arm WAXS detector can measure up to large scattering angle, providing large ''q'' access. | ||
+ | ** E.g. at 16 keV, the WAXS detector at 45° reaches 6 Å<sup>−1</sup> (realspace distance of 0.1 nm). | ||
===Resolution=== | ===Resolution=== | ||
Line 23: | Line 28: | ||
===Flux=== | ===Flux=== | ||
− | * | + | At sample position: |
+ | * 5 ×10<sup>11</sup> ph/s/0.01%bw (9 keV, 15 µm beam, 150 mA ring current) | ||
===Beam Size=== | ===Beam Size=== | ||
* Unfocused beam sizes ~200 µm | * Unfocused beam sizes ~200 µm | ||
* Focusing (H and V) available to ~10 µm (ultimate goal ~2 µm) | * Focusing (H and V) available to ~10 µm (ultimate goal ~2 µm) | ||
+ | |||
+ | ===Coherence=== | ||
+ | CHX is a high-coherence beamline. It will ultimately deliver fully coherent beams. | ||
==Access== | ==Access== | ||
− | CHX is | + | Access to CHX beamtime is available through the [http://www0.bnl.gov/ps/PASS/ NSLS-II proposal system]. Interested users should contact beamline staff. |
+ | |||
+ | ==Users== | ||
+ | * Users can submit bug reports for beamline software using github: | ||
+ | *# Go to: [https://github.com/NSLS-II-CHX/CHX_BugReport https://github.com/NSLS-II-CHX/CHX_BugReport] | ||
+ | *# If you don't have a github account, click "Sign up" (upper right corner). On the next page, scroll down to the bottom, and click "Create an account". Follow the instructions to make your new account (free of course!). | ||
+ | *# Once you have a github account, click "Sign In" (upper right corner). | ||
+ | *# At the upper right corner, click '+' and a popup list will appear. Click 'New issue' and post your issue according to the instruction. | ||
+ | |||
+ | ==Training== | ||
+ | * [https://www.bnl.gov/ps/training/Beamline-BST-Forms/PS-BST-11-ID.pdf Beamline Specific Training Form] | ||
==See Also== | ==See Also== |
Latest revision as of 07:46, 29 August 2019
The Coherent Hard X-ray (CHX) beamline at NSLS-II is a synchrotron undulator-based instrument dedicated to nanometer-scale dynamics. It sits at beamport 11-ID. The instrument is primarily focused on enabling XPCS (X-ray Photon Correlation Spectroscopy) measurements of speckle fluctuation; measurement of the time correlation function can be used to quantify dynamics. Due to the high coherent brightness of the NSLS-II storage ring, CHX will enable measurements over timescales previously inaccessible.
Although CHX is focused on XPCS, it is also capable of exploiting its high beam coherence in other ways, such as coherent scattering or CDI. Additionally, the beamline is capable of more traditional scattering experiments, such as SAXS and WAXS.
Contents
Capabilities
CHX can perform a variety of experiments:
- XPCS
- Coherent scattering
- SAXS
- WAXS
- All of these experiments can also be performed in grazing-incidence mode (GISAXS/GIWAXS, etc.).
Performance
Energy
- Can perform experiments from 6 keV to 16 keV.
- Energy resolution (double crystal monochromator): 10−4
q-range
- Maximum SAXS detector distance is 15 m, offering access to very small q values.
- E.g. at 9 keV, and SAXS detector at 15m, one could reach q = 0.00006 Å−1 (realspace distance of 9 microns).
- Goniometer arm WAXS detector can measure up to large scattering angle, providing large q access.
- E.g. at 16 keV, the WAXS detector at 45° reaches 6 Å−1 (realspace distance of 0.1 nm).
Resolution
TBD
Flux
At sample position:
- 5 ×1011 ph/s/0.01%bw (9 keV, 15 µm beam, 150 mA ring current)
Beam Size
- Unfocused beam sizes ~200 µm
- Focusing (H and V) available to ~10 µm (ultimate goal ~2 µm)
Coherence
CHX is a high-coherence beamline. It will ultimately deliver fully coherent beams.
Access
Access to CHX beamtime is available through the NSLS-II proposal system. Interested users should contact beamline staff.
Users
- Users can submit bug reports for beamline software using github:
- Go to: https://github.com/NSLS-II-CHX/CHX_BugReport
- If you don't have a github account, click "Sign up" (upper right corner). On the next page, scroll down to the bottom, and click "Create an account". Follow the instructions to make your new account (free of course!).
- Once you have a github account, click "Sign In" (upper right corner).
- At the upper right corner, click '+' and a popup list will appear. Click 'New issue' and post your issue according to the instruction.
Training
See Also
- Official site
- Official summary PDF
- chxtools on GitHub