Difference between revisions of "CMS:Sample area"
KevinYager (talk | contribs) (Created page with "* PDF describing sample area (March 2017)") |
MasaFukuto (talk | contribs) (→See Also) |
||
(2 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | |||
+ | ==Photos== | ||
+ | [[Image:sample_area01.png|800px|center]] | ||
+ | Note that the on-axis camera (upstream), and nosecone (downstream) can be removed to make additional space inside the chamber. | ||
+ | |||
+ | ==Dimensions== | ||
+ | Dimensions of available sample area: | ||
+ | * Up to 4" along the beam | ||
+ | * Up to 4" below the beam | ||
+ | * Up to 8" above the beam | ||
+ | * Up to 15" towards the front chamber door (outboard) | ||
+ | * Up to 4" towards the back chamber door (inboard) | ||
+ | |||
+ | ==Screw-hole pattern on Huber (th/chi) stage surface== | ||
+ | [[Image:sample_area02.png|600px|center]] | ||
+ | * th is 'sth' in CMS ophyd environment | ||
+ | |||
+ | ==Screw-hole pattern on Newport GTS30V jack== | ||
+ | This thread pattern is available if th/chi stage is removed. | ||
+ | [[Image:sample_area03.png|600px|center]] | ||
+ | * vertical motion is 'smy' in CMS ophyd environment | ||
+ | |||
+ | ==See Also== | ||
* [[File:Sample area v2.pdf|PDF describing sample area (March 2017)]] | * [[File:Sample area v2.pdf|PDF describing sample area (March 2017)]] | ||
+ | * [[File:CMS_sample_setup_2017-3.pdf|PDF describing sample capabilities (as of Fall 2017)]] |
Latest revision as of 09:02, 13 February 2018
Contents
Photos
Note that the on-axis camera (upstream), and nosecone (downstream) can be removed to make additional space inside the chamber.
Dimensions
Dimensions of available sample area:
- Up to 4" along the beam
- Up to 4" below the beam
- Up to 8" above the beam
- Up to 15" towards the front chamber door (outboard)
- Up to 4" towards the back chamber door (inboard)
Screw-hole pattern on Huber (th/chi) stage surface
- th is 'sth' in CMS ophyd environment
Screw-hole pattern on Newport GTS30V jack
This thread pattern is available if th/chi stage is removed.
- vertical motion is 'smy' in CMS ophyd environment