Difference between revisions of "X9"

From GISAXS
Jump to: navigation, search
(Detectors)
Line 42: Line 42:
 
==Detectors==
 
==Detectors==
 
====Dectris Pilatus 1M (SAXS)====
 
====Dectris Pilatus 1M (SAXS)====
* [http://www.dectris.com/sites/pilatus300k.html Specs]
+
* Hybrid pixel detector.
 +
* [https://www.dectris.com/pilatus3_specifications.html#main_head_navigation Specs]
 
* Format: 981×1043 = 1,023,183 pixels.
 
* Format: 981×1043 = 1,023,183 pixels.
 
* Pixel size: 172×172 µm<sup>2</sup>.
 
* Pixel size: 172×172 µm<sup>2</sup>.
 
* Area: 168.7×179.4 mm<sup>2</sup>.
 
* Area: 168.7×179.4 mm<sup>2</sup>.
 
  
 
====Mar CCD (SAXS)====
 
====Mar CCD (SAXS)====
Line 56: Line 56:
  
 
====Dectris Pilatus 300k (SAXS)====
 
====Dectris Pilatus 300k (SAXS)====
 +
* Hybrid pixel detector.
 
* [http://www.dectris.com/sites/pilatus300k.html Specs]
 
* [http://www.dectris.com/sites/pilatus300k.html Specs]
 
* Format: 487×619 = 301,453 pixels.
 
* Format: 487×619 = 301,453 pixels.
Line 62: Line 63:
  
 
====Photonic Science (WAXS)====
 
====Photonic Science (WAXS)====
 +
* Fiber-coupled CCD detector.
 
* Outputs 16-bit Grayscale TIFF  files with MSB endianess.
 
* Outputs 16-bit Grayscale TIFF  files with MSB endianess.
 
* Pixel size (1042×1042): 101.7 μm.
 
* Pixel size (1042×1042): 101.7 μm.

Revision as of 17:12, 3 June 2014

X9 is an x-ray synchrotron beamline at the National Synchrotron Light Source (NSLS), Brookhaven National Lab (BNL). It is a joint beamline between the NSLS and the Center for Functional Nanomaterials. The instrument is optimized for doing Small-Angle X-ray Scattering (SAXS) and Grazing-Incidence Small-Angle X-ray Scattering (GISAXS), as well as wide-angle Grazing-Incidence X-ray Diffraction (GID/GIXD/GIWAXS).

X9 NSLS 01.jpgX9 NSLS 02.jpg

Capabilities

X9 hutch layout

X9 can perform a variety of x-ray scattering experiments:

  • SAXS and WAXS on powders or solutions in capillaries.
  • SAXS/WAXS (simultaneous) on proteins or other macromolecules in solution, using a full-vacuum path and a flow-through cell (for robust background subtraction).
  • GISAXS and GIWAXS on thin films.

Performance

Energy range

Can perform experiments from 6 keV to 20 keV.

q-range

The instrument can capture data on both a SAXS and WAXS detector (either simultaneously or sequentially). The q-range depends on x-ray energy and the sample-detector distance. For SAXS, one can typically obtain (e.g. for 13.5 keV):

  • 5.4 m: 0.002 Å−1 to 0.1 Å−1 (314 nm to 6.3 nm)
  • 4.1 m: 0.005 Å−1 to 0.2 Å−1 (125 nm to 3.5 nm)
  • 3.0 m: 0.004 Å−1 to 0.2 Å−1 (157 nm to 3.5 nm)
  • 2.0 m: 0.010 Å−1 to 0.4 Å−1 (63 nm to 1.6 nm)
  • 1.5 m: 0.011 Å−1 to 0.45 Å−1 (63 nm to 1.4 nm)

For WAXS, standard configurations yields approximately (for 13.5 keV):

  • 0.235 m (sample inside chamber): 0.13 Å−1 to 4.1 Å−1 (4.8 nm to 0.15 nm)
  • ~0.4 m (sample upstream of chamber): 0.15 Å−1 to 2.1 Å−1 (4.2 nm to 0.3 nm)

Resolution

  • SAXS: Pixel-limited resolution at 5 m (sample-detector) is ~0.0017°, or 0.0002 Å−1 (at ~13.5 keV).
  • WAXS: Pixel-limited resolution is ~0.04°, or 0.0046 Å−1 (at ~13.5 keV). Actual resolution depends on experimental setup and sample size.

Flux

  • At 10 keV, flux capture by mirrors is ~2×1012 ph/s/0.01%bw
  • At 10 keV, flux at sample is ~5×1011 ph/s/0.01%bw
  • At 10 keV, microfocused (10 um), flux at sample is ~2×1011 ph/s/0.01%bw

Beam Size

  • TSAXS: Typical beam size is ~150 µm horizontal and ~100 µm vertical.
  • GISAXS: Typical beam size is ~120 µm horizontal and ~50 µm vertical.
  • Microbeam: Beam can be focused to ~15 µm (horizontal and vertical).

Detectors

Dectris Pilatus 1M (SAXS)

  • Hybrid pixel detector.
  • Specs
  • Format: 981×1043 = 1,023,183 pixels.
  • Pixel size: 172×172 µm2.
  • Area: 168.7×179.4 mm2.

Mar CCD (SAXS)

  • Fiber-coupled CCD detector.
  • Specs
  • Outputs 16-bit Grayscale TIFF files with MSB endianess.
  • Pixel size (using 1024×1024 binning) is 161 μm (software says 158 um).
  • Active area is 165 mm diameter.

Dectris Pilatus 300k (SAXS)

  • Hybrid pixel detector.
  • Specs
  • Format: 487×619 = 301,453 pixels.
  • Pixel size: 172×172 µm2.
  • Area: 83.8×106.5 mm2.

Photonic Science (WAXS)

  • Fiber-coupled CCD detector.
  • Outputs 16-bit Grayscale TIFF files with MSB endianess.
  • Pixel size (1042×1042): 101.7 μm.
  • Detector image is 106 mm in diameter.

Access

X9 is available through NSLS or CFN user programs. However, with NSLS shutting down permanently in September 2014, new proposals are no longer being accepted.

Safety

Users must complete NSLS safety training, as well as receive beamline-specific training:

See Also