Difference between revisions of "Beamlines"
KevinYager (talk | contribs) |
KevinYager (talk | contribs) (→Available Labscale Instruments) |
||
Line 40: | Line 40: | ||
| [[CFN]] | | [[CFN]] | ||
| Available to users. | | Available to users. | ||
− | | | + | | This labscale instrument is available to users. Of course a labscale instrument will not have the flux or resolution of a synchrotron beamline; nevertheless this instrument is optimized for resolution, while providing sufficient flux for measuring strongly scattering systems (e.g. nanoparticles). The sample environment is under vacuum, and offers both transmission-mode and grazing-incidence stages. |
| [[SAXS]], [[WAXS]], [[GISAXS]], [[GIWAXS]] | | [[SAXS]], [[WAXS]], [[GISAXS]], [[GIWAXS]] | ||
| [[Cu K-alpha|8.04 keV]] | | [[Cu K-alpha|8.04 keV]] | ||
| 0.005 Å<sup>−1</sup> to 0.3 Å<sup>−1</sup> (up to ~2 Å<sup>−1</sup> using image plate). | | 0.005 Å<sup>−1</sup> to 0.3 Å<sup>−1</sup> (up to ~2 Å<sup>−1</sup> using image plate). | ||
− | | Available through [http://www.bnl.gov/cfn/user/ CFN | + | | Available through [http://www.bnl.gov/cfn/user/ CFN user program]. |
|- | |- | ||
|} | |} |
Revision as of 11:37, 3 June 2014
The following is a list of x-ray scattering beamlines available to the user community:
Available Synchrotron Beamlines
Beamline | Facility | Status | Description | Techniques | Energy range | q-range | Access |
---|---|---|---|---|---|---|---|
X9 | NSLS | Running until Sept. 2014 | X9 is an undulator-based (high-flux) and high-resolution beamline that can perform transmission and grazing-incidence scattering across a wide q-range (simultaneous SAXS/WAXS possible). | SAXS, WAXS, GISAXS, GIWAXS | 6 keV to 20 keV | 0.002 Å−1 to 4.2 Å−1 | Through NSLS or CFN user programs. (No longer accepting proposals.) |
Available Labscale Instruments
Instrument | Facility | Status | Description | Techniques | Energy range | q-range | Access |
---|---|---|---|---|---|---|---|
Bruker Nanostar | CFN | Available to users. | This labscale instrument is available to users. Of course a labscale instrument will not have the flux or resolution of a synchrotron beamline; nevertheless this instrument is optimized for resolution, while providing sufficient flux for measuring strongly scattering systems (e.g. nanoparticles). The sample environment is under vacuum, and offers both transmission-mode and grazing-incidence stages. | SAXS, WAXS, GISAXS, GIWAXS | 8.04 keV | 0.005 Å−1 to 0.3 Å−1 (up to ~2 Å−1 using image plate). | Available through CFN user program. |
Future Synchrotron Beamlines
Beamline | Facility | Status | Description | Techniques | Energy range | q-range | Access |
---|---|---|---|---|---|---|---|
CMS | NSLS-II | Under construction. | CMS is an bending-magnet beamline being constructed at NSLS-II, based in part on the design and hardware at X9 (NSLS). The beamline will be able to perform transmission and grazing-incidence scattering across a wide q-range (simultaneous SAXS/WAXS possible), and will emphasize automation, high-throughput, and in-situ measurements. | SAXS, WAXS, GISAXS, GIWAXS | 10 keV to 17 keV | 0.002 Å−1 to 4.2 Å−1 | Will be available through NSLS-II user program. |
SMI | NSLS-II | Under construction. | SMI is a undulator-based beamline being constructed at NSLS-II. SMI will be a high-flux and high-resolution instrument optimized for grazing-incidence measurements on interfaces, though also capable of performing world-class transmission scattering experiments. | SAXS, WAXS, GISAXS, GIWAXS, XR | ~2 keV to 24 keV | SAXS and WAXS | Will be available through NSLS-II user program. |